Load
Teltonika RUTX50 wiring diagram
Give your camper’s 5G router a dedicated, protected DC supply. See the RUTX50’s power pins and negative return, then adjust the always-on energy allowance to your use.
Free, no account needed.
- DC input range
- 9–50 V
- Example supply
- 12 V DC
- Planning power allowance
- 18 W · editable
Checked against the manufacturer manual, Nov 2026.
Wiring diagram
A dedicated supply for camper internet
The fused positive goes to pin 1; the dedicated return goes to pin 2. Pins 3 and 4 are digital I/O. The branch fuse is an example choice to check against the actual harness.

The 18 W allowance and 3 A ATC branch fuse are editable example choices. Check actual router demand, supplied pigtail and source protection. Use a dedicated negative return. The drawing covers DC power; antennas, Ethernet and SIM setup are separate. Manufacturer installation manual
Get wire sizes for my setupFree, no account needed.
Quick answers
Cable and fuse
1.5 mm² (16 AWG) with a 3 A fuse for a 3 m one-way run (12 V system). Sizes for other lengths
Router supply cable reference
The example budgets 18 W for continuous use. That is an editable planning allowance, not a manufacturer maximum or a claim about idle draw.
3 m one way
12 V system
- Wire
- 1.5 mm² · 16 AWG
- Example fuse
- 3 A
- Design current
- 1.5 A
- Voltage drop
- 0.9%
Cable size by run length
| One way | Wire | Fuse | Voltage drop |
|---|---|---|---|
| 1 m | 1.5 mm² · 16 AWG | 3 A | 0.3% |
| 2 m | 1.5 mm² · 16 AWG | 3 A | 0.6% |
| 3 m (worked example above) | 1.5 mm² · 16 AWG | 3 A | 0.9% |
| 5 m | 1.5 mm² · 16 AWG | 3 A | 1.5% |
| 8 m | 1.5 mm² · 16 AWG | 3 A | 2.4% |
Same circuit and current, sized by Crimp's engine at each length. Longer runs, warmer spaces or engine rooms need the editor's full check.
Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.
Already have a cable size? Check a simple copper run at your current and length with the DC voltage drop calculator in mm² or AWG.
Run-length and manufacturer assumptions
The editable example uses 10 ft (3 m) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.
The 18 W allowance and 3 A ATC branch fuse are editable example choices. Check actual router demand, supplied pigtail and source protection. Use a dedicated negative return. The drawing covers DC power; antennas, Ethernet and SIM setup are separate. Manufacturer installation manual
Supporting parts
- 6 m total of 1.5 mm² (16 AWG) marine cable
- Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
- 3 A fuse and holder on the positive run
- Heat-shrink, strain relief and terminal boots sized to the cable
Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.
Installation notes
Before you install.
Open a question for model-specific guidance and sources.
Verified against the manufacturer's documentation (rev. Powering Options and Power Consumption wiki pages, checked 2026-11-26), checked 2026-11-26. Manufacturer documentation →
Which Teltonika RUTX50 is this?
This is the RUTX50 5G router, represented by its four-pin DC power and digital-I/O connector. The input accepts 9–50 V DC. The example uses a dedicated 12 V house-battery branch; antennas, Ethernet and mobile-network settings are separate.
How is the Teltonika RUTX50 wired?
Pin 1 takes protected positive and pin 2 takes a dedicated negative return. Pin 3 is digital input and pin 4 is digital output; neither is an extra supply contact. Check the connector orientation against Teltonika’s powering guide.
The example branch fuse is an editable choice, not a Teltonika-prescribed rating. Match protection to the supplied pigtail, extensions and source. Use the Technical reference when adjusting the cable route.
What should I bear in mind with the Teltonika RUTX50?
Budget for continuous operation without treating one consumption figure as universal.
- Energy allowance: this model uses an editable 18 W budget. Teltonika’s measurements include 5.18 W at 12 V with a data connection idle and 16.21 W in its loaded 12 V test. These are measured test averages; the planning allowance is not a manufacturer maximum.
- PoE: LAN1 accepts passive Mode B power. It is not an IEEE 802.3af/at/bt input and supplies no PoE output. Follow the powering guide, including its dedicated-return guidance.
- A nominal 48 V battery can charge above the router’s 50 V input ceiling. Do not infer compatibility from its nominal label.
What do owners and installers say about the Teltonika RUTX50?
Supply checks are part of diagnosing unexpected restarts. In a reboot discussion, a PoE-powered owner reported restarts under activity and support asked for a test with the original supply. The thread does not confirm that insufficient power caused the fault; firmware, logs and configuration also needed investigation.
What belongs around the Teltonika RUTX50?
Open the dedicated-supply example above and set your actual cable length and daily use. A Blue Sea 5029 fuse block can organize other camper branches. Explore campervan wiring examples and check extensions with the wire-size calculator.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
RUTX50 5G router with a 9–50 V DC input. Uses an editable 18 W, always-on planning allowance, not a manufacturer maximum or idle measurement. Pins 1/2 supply power; pins 3/4 are digital I/O.
- DC input range
- 9–50 V
- Example supply
- 12 V DC
- Planning power allowance
- 18 W · editable
- Planning use
- 24 hours per day
- Power connector
- Pin 1 positive · pin 2 ground
- Optional PoE input
- LAN1 · passive Mode B
Terminal map
Pin 1: power positive (red). Pin 2: ground (black). Pin 3: digital input (green). Pin 4: digital output (white). LAN1 also supports passive Mode B PoE; it is not an IEEE 802.3af/at/bt input or a PoE output.
1 · POWER +
positive · input
2 · GND
negative · input
3 · INPUT
signal · input
4 · OUTPUT
signal · output
A dash means a current rating is not specified here.
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.
Read how the sizing worksNext step
Plan your installation with RUTX50 5G.
Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.
Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.