Black Week: 30% off Lifetime and Pro. Ends Sunday.

Campervan wiring diagram

200Ah lithium campervan wiring diagram with 400W solar, DC-DC & shore charger

This is a full-time van that skips the inverter: a 200 Ah LiFePO4 battery charged by 400 W of roof solar, a 50 A DC-DC charger while driving and a 30 A mains charger whenever you plug into a hook-up. Everything it runs is 12 V: a large compressor fridge, lights, a roof fan, a water pump, USB-C, Starlink Mini and a diesel heater. With three ways to charge, a winter week of short drives and grey days is covered by one night on a campsite hook-up. It suits people who want to stay out year-round without cooking on electricity.

The wiring diagram

20 components · 34 conductors · 12 V

Open this diagram in Crimp
200Ah lithium campervan wiring diagram with 400W solar, DC-DC & shore charger: Vehicle starter battery, DC-DC charger 50 A, Roof solar panel 200 W 1, Roof solar panel 200 W 2, Solar isolator, Solar charge controller and 14 more parts, with the wire size and fuse marked on each cable.

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.

View full screen

Red = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.

What it powers

Each load's draw comes from its catalog entry. The hours are this guide's assumptions; change them to yours.

Loads and daily energy use
LoadDrawHours a dayEnergy a dayWhy
Compressor fridge66 W6 h396 WhA compressor fridge cycles; about a quarter of the day, more in hot weather.
LED lights24 W5 h120 WhLong evenings.
Roof fan60 W4 hsummer only240 WhWarm evenings at full speed; lower speeds draw less.
Water pump72 W0.25 h18 WhAbout 15 minutes of washing and cooking.
USB-C charging60 W3 h180 WhA laptop and phones at full 60 W.
Starlink Mini30 W8 h240 WhA working day online.
Diesel heater40 W10 hwinter only400 WhEvenings and overnight in cold weather; nothing in summer.
Total a day1,194 Wh summer
1,354 Wh winter

Energy budget

What goes in against what comes out, per day. Solar assumes 5 peak sun hours in summer and 1.5 in winter at 75 % panel-to-battery efficiency; the alternator figure assumes 1 hour of driving.

A summer day

Solar in
+1,500 Wh
Driving in (1 h)
+640 Wh
Used
−1,194 Wh
Net
+946 Wh

The battery ends the day fuller than it started.

A winter day

Solar in
+450 Wh
Driving in (1 h)
+640 Wh
Used
−1,354 Wh
Net
−264 Wh

The battery loses about 13 % of its usable charge a day; a full battery lasts about 7 days like this.

With no charging at all, the 2,048 Wh above a 20 % reserve lasts about 1.5 days at the larger daily use. In Crimp, switch loads on and off in the drawing to see the live current and runtime.

Parts list

20 parts. Each links to its Crimp page with the manufacturer's ratings and installation notes.

Cable and fuse sizes

Sized by Crimp's ABYC E-11 based engine for these lengths. Lengths are one way; AWG is the approximate counterpart of the metric size.

Cable table units
Cable schedule
ConnectionLengthWireDesign currentFuseDrop
C1 · Vehicle starter battery +
→ DC-DC charger 50 A ALT +
3 m9.8 ft16 mm²AWG 6manufacturer size59.3 A—1.62%
C2 · Vehicle starter battery −
→ Negative bus bar − 2
3 m9.8 ft16 mm²AWG 6manufacturer size59.3 A—1.62%
C3 · DC-DC charger 50 A OUT +
→ Positive bus bar 1
1 m3.3 ft16 mm²AWG 6manufacturer size50 A65 A0.43%
C4 · DC-DC charger 50 A NEG −
→ Negative bus bar − 3
1 m3.3 ft16 mm²AWG 6manufacturer size9.3 A—0.08%
C5 · Roof solar panel 200 W 1 +
→ Solar isolator IN +
4 m13.1 ft4 mm²AWG 118.8 A15 A0.69%
C6 · Roof solar panel 200 W 2 +
→ Solar isolator IN +
4 m13.1 ft4 mm²AWG 118.8 A15 A0.69%
C7 · Roof solar panel 200 W 1 −
→ Solar isolator IN −
4 m13.1 ft2.5 mm²AWG 138.8 A—1.10%
C8 · Roof solar panel 200 W 2 −
→ Solar isolator IN −
4 m13.1 ft2.5 mm²AWG 138.8 A—1.10%
C9 · Solar isolator OUT +
→ Solar charge controller PV +
50 cm1.6 ft1.5 mm²AWG 1617.7 A25 A0.46%
C10 · Solar isolator OUT −
→ Solar charge controller PV −
50 cm1.6 ft1.5 mm²AWG 1617.7 A—0.46%
C11 · Solar charge controller BATT +
→ Positive bus bar 2
1 m3.3 ft10 mm²AWG 8manufacturer size50 A60 A0.68%
C12 · Solar charge controller BATT −
→ Negative bus bar − 4
1 m3.3 ft10 mm²AWG 850 A—0.68%
C13 · Mains charger 30 A BATT +
→ Positive bus bar 3
2 m6.6 ft10 mm²AWG 8manufacturer size30 A40 A0.82%
C14 · Mains charger 30 A BATT −
→ Negative bus bar 4 −
2 m6.6 ft10 mm²AWG 8manufacturer size30 A—0.82%
C15 · House battery 200 Ah LiFePO4 +
→ Main battery switch A
30 cm1.0 ft35 mm²AWG 2130 A—0.15%
C16 · Main battery switch B
→ Positive bus bar 4
30 cm1.0 ft35 mm²AWG 2130 A—0.15%
C17 · House battery 200 Ah LiFePO4 −
→ Battery monitor BATT −
30 cm1.0 ft35 mm²AWG 2130 A—0.15%
C18 · Battery monitor LOAD −
→ Negative bus bar 6 −
30 cm1.0 ft35 mm²AWG 2130 A—0.15%
C19 · Positive bus bar 4
→ Fuse block IN +
50 cm1.6 ft10 mm²AWG 830.3 A40 A0.21%
C20 · Fuse block IN −
→ Negative bus bar 5 −
50 cm1.6 ft6 mm²AWG 1030.3 A—0.35%
C21 · Fuse block 1 +
→ Compressor fridge +
3 m9.8 ft6 mm²AWG 105.5 A15 A0.38%
C22 · Compressor fridge −
→ Fuse block 1 −
3 m9.8 ft6 mm²AWG 105.5 A—0.38%
C23 · Fuse block 2 +
→ LED lights +
5 m16.4 ft1.5 mm²AWG 162 A3 A0.91%
C24 · LED lights −
→ Fuse block 2 −
5 m16.4 ft1.5 mm²AWG 162 A—0.91%
C25 · Fuse block 3 +
→ Roof fan +
3 m9.8 ft2.5 mm²AWG 135 A7.5 A0.82%
C26 · Roof fan −
→ Fuse block 3 −
3 m9.8 ft2.5 mm²AWG 135 A—0.82%
C27 · Fuse block 4 +
→ Water pump +
2 m6.6 ft2.5 mm²AWG 136 A7.5 A0.66%
C28 · Water pump −
→ Fuse block 4 −
2 m6.6 ft2.5 mm²AWG 136 A—0.66%
C29 · Fuse block 5 +
→ USB-C charging +
3 m9.8 ft2.5 mm²AWG 135.5 A7.5 A0.90%
C30 · USB-C charging −
→ Fuse block 5 −
3 m9.8 ft2.5 mm²AWG 135.5 A—0.90%
C31 · Fuse block 6 +
→ Starlink Mini +
4 m13.1 ft1.5 mm²AWG 162.3 A3 A0.85%
C32 · Starlink Mini −
→ Fuse block 6 −
4 m13.1 ft1.5 mm²AWG 162.3 A—0.85%
C33 · Fuse block 7 +
→ Diesel heater +
2 m6.6 ft1.5 mm²AWG 164 A7.5 A0.73%
C34 · Diesel heater −
→ Fuse block 7 −
2 m6.6 ft1.5 mm²AWG 164 A—0.73%

A dash means the cable has no fuse of its own: a negative, or a run protected by the fuse upstream of it. Fuses on a battery post are listed with the battery in the drawing.

How it is wired

  1. 01

    Three chargers, one pair of bus bars

    The solar controller, the DC-DC charger and the mains charger each land on the positive and negative bus bars with their own fuse. The battery takes whatever the loads leave over, and the shunt counts it. Solar and the DC-DC charger together give up to 100 A, the battery's charge limit; the mains charger only runs on a hook-up, when the van is not driving.

  2. 02

    The mains charger's AC side

    Only the charger's DC output is drawn. Its mains lead plugs into the van's hook-up circuit: an inlet, an RCD and a breaker, installed as local rules require. Keep the 230 V wiring separate from the 12 V runs.

  3. 03

    One shared negative

    The DCC50S has a single NEG− terminal for every battery, so the vehicle battery's negative, the charger and the house battery all meet at the negative bus bar. The shunt sits between the house battery and that bar, so it counts every amp in and out.

  4. 04

    Same charge voltage everywhere

    Set the solar controller, the DC-DC charger and the mains charger to the same lithium profile, so one does not stop charging early because another has raised the voltage.

Before you build

Crimp's checks on this drawing: 0 critical, 5 to review. They stay visible when you open it.

  • Measure your own cable runs and re-check the sizes in Crimp; the mains charger's cable needs 16 mm² beyond 3 m.
  • Use a fuse at the battery with an interrupt rating suited to a 200 Ah lithium bank, such as class T.
  • Check the two 200 W panels' cold-weather Voc in parallel against the controller's 100 V limit.
  • Check that your alternator can spare the DC-DC charger's input current, and connect the IGN wire on a smart-alternator vehicle.
  • Have the hook-up inlet, RCD and breaker installed to local rules; they are not drawn here.
  • warning: Grounding path missing: Mains charger 30 A
  • warning: Check monitor power: Battery monitor
  • info: Check fuse suitability: House battery 200 Ah LiFePO4
  • info: Check fuse suitability: Vehicle starter battery
  • info: Check battery charge limit

A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer manuals below for your exact parts.

Questions about this system

Do I need an inverter in a campervan?

Only for mains appliances: a kettle, hob, hair dryer or a laptop without a USB-C charger. Everything in this drawing runs on 12 V, which skips the inverter's losses, its 200 A cable and its idle drain. A 30 A mains charger covers the hook-up side, which is what many people want an inverter/charger for.

How long does a 30A charger take to charge a 200Ah lithium battery?

About five to six hours from the 20 % reserve to full. The battery holds about 2,050 Wh above that reserve, and the charger delivers 30 A at around 13 V, roughly 400 W, while the van's loads take their share. A 200 Ah LiFePO4 battery accepts far more, 100 A by its manual, so the charger, not the battery, sets the time.

Can a solar controller, DC-DC charger and mains charger charge the same battery?

Yes. Each has its own fused cable to the bus bars and they add together; each regulates its own output, and the battery takes what the loads leave over. Set them all to the same lithium charge voltage so one does not stop early because another has raised the voltage.

What size cable does a 30A battery charger need?

Victron's table for the Phoenix Smart IP43 12/30 asks for 10 mm² (8 AWG) up to 3 m one way and 16 mm² (6 AWG) from 3 m to 4.5 m, and does not recommend longer runs. This drawing's 2 m run uses 10 mm²; the fuse at the bus bar is sized for that cable.

Is 400W of solar and a DC-DC charger enough without hook-ups?

In summer, comfortably. This drawing uses about 1,190 Wh a day and the panels put back about 1,500 Wh on a sunny day, before any driving. In winter use rises to about 1,350 Wh with the heater, while the panels make about 450 Wh and an hour's driving about 640 Wh. That leaves a shortfall of about 260 Wh a day, so a full battery lasts about a week of short daily drives before it wants a hook-up.

Manufacturer sources

Reviewed 26 November 2026.

Start from this system instead of a blank page.

Open this diagram in Crimp
Keep going200Ah campervan with 400W solar and a 2000W inverterThe same system with an inverter for electric cooking.Keep going100Ah campervan with 200W solar and DC-DCThe smaller system for weekend and holiday trips.Keep goingDC-DC charger sizeCheck whether your alternator can spare the input current.Keep goingWire size calculatorSize the charger cable for your own run length.